Carrier 38GVQ Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Aparelhos de ar condicionado "split system" Carrier 38GVQ. Carrier 38GVQ Instruction manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Installation Instruction
40GVC / 38GVC
40GVQ / 38GVQ
High---W all Ductless Split Systems
Size 9K --- 36K
NOTE: Read the entire instruction manual before starting the installation.
TABLE OF CONTENTS
PAGE
PARTS LIST 1.......................................
SAFETY CONSIDERATIONS 2.........................
SYSTEM REQUIREMENTS 2--3........................
DIMENSIONS 4--6....................................
CLEARANCES 7.....................................
INSTALLATION GUIDE 8.............................
INDOOR UNIT INSTALLATION 8--9.....................
Install Mounting Plate 8.............................
Drill Hole in Wall for Interconnecting Piping, Drain
and Wiring 9.....................................
OUTDOOR UNIT INSTALLATION 9--10..................
Piping Connections 9...............................
Outdoor Unit Wiring Connections 10..................
INSTALL ALL POWER, INTERCONNECTING WIRING AND
PIPING TO INDOOR UNIT 10..........................
SYSTEM VACUUM AND CHARGE 11...................
START--UP 12........................................
WIRING DIAGRAMS 13...............................
TROUBLESHOOTING 14--17...........................
The following parts are included in your indoor unit. Please
contact your dealer if any parts are damaged or missing:
Parts Qty
Mounting Plate 1
Mounting Hardware 7
Remote Control 1
Remote Control Holder 1
Battery (1.5V) 2
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - Installation Instruction

Installation Instruction40GVC / 38GVC40GVQ / 38GVQHigh---W all Ductless Split SystemsSize 9K --- 36KNOTE: Read the entire instruction manual before st

Página 2 - SYSTEM REQUIREMENTS

10Outdoor Unit WiringConnections1. Mount outdoor power disconnect.2. Run power wiring from main box to disconnect per NECand local codes. Set outdoor

Página 3 - 18 AWG 50 ft. (15 m)

11UNIT DAMAGE HAZARDFailure to follow this caution may result in equipmentdamage or improper operation.Never use the system compressor as a vacuum pum

Página 4 - DIMENSIONS -- OUTDOOR

12START--UPTest OperationPerform test operation after completing gas leak and electricalsafety check.1. Push the “ON/OFF” button on Remote Control to

Página 5 - 27.6 (700)

13WIRING DIAGRAMSN S L L N GND N S L GNDGround Ground115-1-60 Low V DC 115-1-60 115-1-60 115-1-60 115-1-60 Low V DC 115-1-6038GV/40GV 9K~12K 115-1-6

Página 6

14TROUBLESHOOTINGThis unit has on--board diagnostics. Error codes will appear on the LED display on the front panel of the indoor unit in place of the

Página 7 - Outdoor Unit

15TROUBLESHOOTING (CONTINUED)Diagnostic Codes38/40GVC/Q 12K, 230vMalfunctionError Code on in-door unitRepair Method/CauseIndoor PCB Malfunction EE Rep

Página 8 - INSTALL MOUNTING PLATE

16TROUBLESHOOTING (CONTINUED)Diagnostic Codes38/40GVC/Q 18k--24k, 230vMalfunctionError Codeon indoor unitRepair Method/CauseSystem high pressure prote

Página 9 - OUTDOOR UNIT INSTALLATION

17TROUBLESHOOTING (CONTINUED)Diagnostic Codes38/40GVC/Q 30k--36k, 230vMalfunctionError Codeon indoor unitRepair Method/CauseDefrosting H1 H1 signal no

Página 10 - Knockout 1

18Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231Manufacturer reserves the right to change, at any time, specifications and

Página 11 - SYSTEM VACUUM AND CHARGE

2SAFETY CONSIDERATIONSInstalling, starting up, and servicing air--conditioning equipmentcan be hazardous due to system pressures, electrical component

Página 12 - OUTDOOR UNIT

3Connecting (Power and ControlCable)Power Wiring:The main power is supplied to the outdoor unit. The field suppliedconnecting cable from the outdoor u

Página 13 - WIRING DIAGRAMS

4DIMENSIONS -- INDOORWDHA12377Unit SizeWIn. (mm)HIn. (mm)DIn. (mm)Net Operating WeightLbs. (Kg)9K 30.3 (770) 11.1 (283) 7.9 (201) 18.7 (8.5)12K 30.3 (

Página 14 - TROUBLESHOOTING

5DIMENSIONS -- OUTDOOR CONTINUED25.9 (658)10.8 (274)28.0 (711)18.5 (470)12.5 (318)11.8 (300)21.7 (551)Unit: IN. (mm)Unit: IN. (mm)A12532Fig. 3 --- 12K

Página 15 - TROUBLESHOOTING (CONTINUED)

6DIMENSIONS -- OUTDOOR CONTINUED14.6(370.8)36(914.4)24(609.6)15.7(398.8)31.1(789.9)38.6(980.4)16.7(424.2)in. (mm)A12379Fig. 5 --- 30K and 36K (Net Ope

Página 16

7CLEARANCESvalve cover The clearance dimensions are necessary for a correct installationand are the minimum permissible distances to adjacent struc

Página 17

8INSTALLATION GUIDEIdeal installation locations include:IndoorUnitS A location where there are no obstacles near inlet and outlet area.S A location wh

Página 18 - Edition Date: 07/13

9DRILL HOLE IN WALL FOR INTERCONNECTINGPIPING, DRAIN AND WIRINGRefrigerant Line RoutingThe refrigerant lines may be routed in any of the four directio

Comentários a estes Manuais

Sem comentários