ARCHITECTS AND ENGINEERSMANUAL
October 2001 Copyright Carrier Corporation Cat. No. 592-075
CONTENTS
Page
APPLICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,3
New Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Carrier Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Application Considerations . . . . . . . . . . . . . . . . . . . . . . 3
PRODUCT OVERVIEW
. . . . . . . . . . . . . . . . . . . . . . .4
PRODUCT FEATURES AND BENEFITS
. . . . 5-11
Quiet Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Most Efficient Performance . . . . . . . . . . . . . . . . . . . . . .5
Efficient Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
No-Rust Weather Last™ Wall Sleeve and
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Removable Front Panel . . . . . . . . . . . . . . . . . . . . . . . . .6
Two-Piece Lifetime Indoor Filter. . . . . . . . . . . . . . . . . . 6
Washable Vent Air Filter . . . . . . . . . . . . . . . . . . . . . . . . 7
Bi-Directional Discharge Grille . . . . . . . . . . . . . . . . . . . 7
Easy Access to Chassis. . . . . . . . . . . . . . . . . . . . . . . . . .8
Hidden Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Enhanced Copper Tubing. . . . . . . . . . . . . . . . . . . . . . . .9
Seamless Basepan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Page
Condensate Drain Valve. . . . . . . . . . . . . . . . . . . . . . . . . 9
Condensate Removal System. . . . . . . . . . . . . . . . . . . . . 9
Heat Pumps Pay Their Own Way. . . . . . . . . . . . . . . . . 10
Heat Pump Energy Savings . . . . . . . . . . . . . . . . . . . . . 11
ORDERING DATA
. . . . . . . . . . . . . . . . . . . . . . . . 12-21
Product Catalog Number . . . . . . . . . . . . . . . . . . . . . . . 12
Factory-Installed Options. . . . . . . . . . . . . . . . . . . . . . . 13
Field-Installed Accessories . . . . . . . . . . . . . . . . . . . . . 14
DIMENSION DRAWINGS AND
INSTALLATION DATA — NEW
CONSTRUCTION
. . . . . . . . . . . . . . . . . . . . . . . . . 22-25
PRODUCT DATA
. . . . . . . . . . . . . . . . . . . . . . . . . 26-30
WIRING DIAGRAMS
. . . . . . . . . . . . . . . . . . . . . 31-36
GUIDE SPECIFICATIONS
. . . . . . . . . . . . . . . . .37,38
TYPICAL WARRANTY
. . . . . . . . . . . . . . . . . . . .39,40
LITERATURE LIST
. . . . . . . . . . . . . . . . . . . . . . . . . . 41
STANDARD COLORS
. . . . . . . . . . . Inside Back Cover
MODEL 52C
PACKAGED TERMINAL
AIR CONDITIONERS
AND HEAT PUMPS
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - CONTENTS

ARCHITECTS AND ENGINEERS’ MANUALOctober 2001 Copyright  Carrier Corporation Cat. No. 592-075CONTENTSPageAPPLICATIONS . . . . . . . . . . . . . . . .

Página 2 - APPLICATIONS

10HEAT PUMPS PAY THEIR OWN WAYHeat pump models are available at a nominal addi-tional cost. In many locales, the payback is realized injust a few mont

Página 3 - Air Infiltration

11HEAT PUMP ENERGY SAVINGSCARRIER HEAT PUMP INITIAL COST VERSUS SAVINGS OVER HEAT/COOL MODELS LEGEND*Computer projections based on full coolin

Página 4 - PRODUCT OVERVIEW

12For immediate assistance, call 1-800-827-7435 or contactyour local Carrier dealer.Standard 52C Unit• Chassis with front panel• Electro-mechanical co

Página 5 - PRODUCT FEATURES AND BENEFITS

13FACTORY-INSTALLED OPTIONSWall Thermostat Control (RC,RP)Carrier’s wall thermostat control option includes:• a standard chassis with front panel• fac

Página 6 - Wall Sleeve

14FIELD-INSTALLED ACCESSORIESWall SleevesIt is recommended that a Carrier sleeve be used with aCarrier chassis.Locating holes in the side panels allow

Página 7 - DISCHARGE GRILLE

15OUTDOOR GRILLESCarrier recommends only the use of Carrier-suppliedgrilles for use on the 52C series units. However, thearchitectural designs of a bu

Página 8 - Easy Service Access

16Outdoor Grille SelectionIMPORTANT: If you wish to use a grille not madeby Carrier for your Carrier unit(s), contactthe Carrier Application Engineeri

Página 9 - CONDENSATE REMOVAL

17Hardwire KitPart No.: HARDWIRE-KIT-1PKThis accessory hardwire kit provides a permanent con-nection to the unit. Electrical hard wiring is requiredwh

Página 10 - How The Heat Pump Works

18SubbasePart No.: SUBBASE-NON-ELECPart No.: SUBBASE-230V-15APart No.: SUBBASE-230V-20APart No.: SUBBASE-230V-30APart No.: SUBBASE-265V-15APart No.: S

Página 11 - HEAT PUMP ENERGY

19Subbase Power Disconnect SwitchPart No.: SUBBASE-SWITCHThe subbase power disconnect switch provides arecessed power disconnect for the PTAC unit whe

Página 12 - ORDERING DATA

2Whether you are designing a new structure or replac-ing packaged terminal air conditioning units in anexisting building, Carrier will meet your needs

Página 13 - Corrosion Protection (CP,RP)

20Manual Changeover WallThermostatPart No.: HH01AD045 (for heat/cool and heat pumpmodels)This manual changeover wall thermostat provides areliable and

Página 14 - ORDERING DATA (cont)

21Replacement FiltersPart No.: AIR-FILTER-10PKThe Carrier 52C model replacement air filters come inpackages of 10. The filters save energy by preventi

Página 15 - Standard Grille

22TYPICAL WALL INSTALLATIONProper building practices must be used when con-structing a wall opening to support a PTAC wall sleeveand chassis.If practi

Página 16

23WALL SLEEVE MOUNTING DIMENSIONS FOR STANDARD AND ACCESSORY GRILLESMAIN STUDJACK STUDCRIPPLEFLOORSUB-FLOOR42 1/8”16 1/4”JACK STUDSHEADER- 4’ x 4’ OR(

Página 17 - Condensate Drain Kit

24MINIMUM CLEARANCE FOR OUTDOOR DISCHARGE AIRTYPICAL LATERAL DUCT INSTALLATIONDIMENSION DRAWINGS AND INSTALLATIONDATA — NEW CONSTRUCTION (cont)36"

Página 18

2552C WITH SUBBASETYPICAL WALL AND DEEP WALL INSTALLATIONNOTES:1. Accessory subbase is required for applications where:• Wall sleeve extends 4 or more

Página 19 - Security Door Kit

26PERFORMANCE AND ELECTRICAL DATAMODEL 52CQ (230/208-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 380-93.†Coeffici

Página 20

27PERFORMANCE AND ELECTRICAL DATAMODEL 52CQ (265-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 380-93.†Coefficient

Página 21 - Energy Management Kit

28PERFORMANCE AND ELECTRICAL DATAMODEL 52CE (230/208-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310-93.†Electric r

Página 22 - DATA — NEW CONSTRUCTION

29PERFORMANCE AND ELECTRICAL DATAMODEL 52CE (265-1-60)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310-93.†Electric resis

Página 23 - AND ACCESSORY GRILLES

3APPLICATION CONSIDERATIONSInstallation instructions are shipped with all PTACunits. It is important that air conditioning systems beproperly sized an

Página 24 - 52C Lateral Duct

30INDOOR SOUND DATAThe table below indicates the approximate indoorsound level of a 52C unit. Tests were conducted in theCarrier Sound Testing Laborat

Página 25 - WALL INSTALLATION

31WIRING DIAGRAMS52CQ — Typical Wiring Schematic for Standard Units

Página 26 - PRODUCT DATA

32WIRING DIAGRAMS (cont)52CQ — Typical Wiring Schematic for Wall Thermostat Control Units

Página 27 - RECEPTACLES AND FUSE TYPES

3352CE — Typical Wiring Schematic for Standard Units

Página 28 - PRODUCT DATA (cont)

34WIRING DIAGRAMS (cont)52CE — Typical Wiring Schematic for Wall Thermostat Control Units

Página 29

35FRONT DESK SWITCH PANEL24-VTRANSFORMER(SEE NOTE)PTAC #1PTAC #2PTAC #NROOM 100 ROOM 101 ROOM NBWBWBWLEGENDNOTES:1. To size transformer, use the follo

Página 30

36WIRING DIAGRAMS (cont)RYWGOCRYWGOCRYWGOCRYWGOCRYWGOCT’STATMASTERPTACUNIT 1UNIT 2UNIT 3Typical Wiring for Multiple 52C PTAC Units Connected to 1 Wall

Página 31 - WIRING DIAGRAMS

37PACKAGED TERMINALCOOLING UNITWITH HEAT PUMP ORELECTRIC HEATINGHVAC Guide SpecificationsSize Range: Cooling: 6,900 to 15,000 BtuhHeating: 6,000 to 14

Página 32 - WIRING DIAGRAMS (cont)

38L. Special Features:Certain standard features are not applicable whenthe features designated are specified. Contactyour local Carrier Sales Office f

Página 33

39TYPICAL WARRANTY

Página 34

4This section summarizes product features covered indetail in later sections of this manual: PRODUCT OVERVIEWCOPPER TUBEALUMINUMFIN COILSDISCHARGEGRIL

Página 35

40TYPICAL WARRANTY (cont)

Página 36

41*Extended metal wall sleeves also available in 26 in. and 28 in. deep.†Custom colors are also available.ACCESSORYLITERATUREFORM NUMBERPART NUMBER DE

Página 40 - TYPICAL WARRANTY (cont)

5The 52C model is a single-package, through-the-wallunit for heating and cooling hotel rooms, offices,apartments, condominiums, and residential additi

Página 41 - ACCESSORIES

6NO-RUST WEATHER LAST™WALL SLEEVE AND FRONTPANELThe indoor front panel and non-insulated wall sleeveuse nonmetallic compounds that never rust or corro

Página 42

7WASHABLE VENT AIR FILTERThe unique vent system is activated by a two-positioncontrol. Fresh outside air is redirected by the vent doorto an inside lo

Página 43

8EASY ACCESS TO CHASSISAccess to the chassis simply requires removing fourscrews and then sliding the chassis out of the sleevefor service. HIDDEN CON

Página 44

9ENHANCED COPPER TUBINGEnhanced copper tubing is more efficient and durableand can be repaired in the field, if required.Because copper is a very stab

Comentários a estes Manuais