E3 -- If AC/HP Control cannot properly read outdoor temperature, and it is needed
for proper operation, display will indicate “----” in the outdoor temperature location.
E4 -- If AC/HP Controls internal memory fails, E4 will be displayed. Replace
AC/HP Control.
Table 3 can be used as a troubleshooting tool for determining which outputs will be
active for a particular configuration and each operating mode.
When replacing a failed component such as an equipment control module or a
display module, the installer should replace both parts as a matched set. It is very
easy to accidentally mix an A/C or HP display with a PAC equipment control
module. When this happens, some functions appear in the setup while others do not.
This can be very confusing to troubleshoot. Verify that both parts have the same
model and serial number when troubleshooting the thermostat.