Vista de página 0
OPERATING INSTRUCTIONS English
SUPRA 450/550/750/850/950 – 750Mt°/850Mt°/950Mt° & Nordic version
62-61107-02 3
1. INTRODUCTION
This guide has been prepared for the operator of Carrier Transicold refrigeration units. It contains
basic instructions for the daily operation of the refrigeration unit as well as safety information,
troubleshooting tips, and other information that will help you to deliver the load in the best possible
condition.
Please take the time to read the information contained in this booklet and refer to it whenever you
have a question about the operation of your Carrier Transicold unit. This manual refers to the standard
model. Some options may not appear in it, and in such cases you are requested to consult our
Technical Services.
Your refrigeration unit has been engineered to provide long, trouble-free performance when it is
properly operated and maintained. The checks outlined in this guide will help to minimize on the road
problems. In addition, a comprehensive maintenance program will help to insure that the unit
continues to operate reliably. Such a maintenance program will also help to control operating costs,
increase the unit's working life, and improve performance.
When having your unit serviced, be sure to specify genuine Carrier Transicold replacement parts for
the highest quality and best reliability.
At Carrier Transicold, we are continually working to improve the products that we build for our
customers. As a result, specifications may change without notice.
CONTENTS
1.
INTRODUCTION ..........................................................................................................................3
2. IDENTIFICATION .........................................................................................................................5
3. WARNINGS AND PRECAUTIONS ..............................................................................................5
3.1. Warning stickers maintenance ................................................................................................9
4. PRODUCT LOADING .................................................................................................................10
5. RECOMMENDED TRANSPORT TEMPERATURES .................................................................12
6. QUICK GLANCE ON THE DISPLAY BOARD ............................................................................13
6.1. Cab control ............................................................................................................................13
7. OPERATION...............................................................................................................................15
7.1. Pretrip inspection...................................................................................................................15
7.2. Starting the unit – Road operation.........................................................................................16
7.3. tarting the unit – Standby operation ....................................................................................16 S
7.3.1.
Standby operation guidelines ........................................................................................16
7.4. Unit shut down.......................................................................................................................17
7.5. To change setpoint temperature ...........................................................................................17
7.6. Manual defrost.......................................................................................................................17
7.7. To display unit data ...............................................................................................................17
7.8. To change a function.............................................................................................................18
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1

OPERATING INSTRUCTIONS English SUPRA 450/550/750/850/950 – 750Mt°/850Mt°/950Mt° & Nordic version 62-61107-02 3 1. INTRODUCTION This guide has

Página 2

62-61107-02 12 5. RECOMMENDED TRANSPORT TEMPERATURES Below are some general recommendations on product transport temperatures and operating modes f

Página 3

62-61107-02 6. QUICK GLANCE ON THE DISPLAY BOARD 6.1. Cab control Keep the fold out sheet while reading the instructions. This refrigeration unit

Página 4 - EPROM 4.05 – FOR MULTI TEMP

62-61107-02 9. Manual defrost key The MANUAL DEFROST key places the unit in a defrost cycle. Under most conditions it is not necessary to defrost t

Página 5

62-61107-02 7. OPERATION 7.1. Pretrip inspection The pre-trip inspection should be performed before picking up any load. This inspection is essent

Página 6

62-61107-02 7.2. Starting the unit – Road operation 1. Complete the PRETRIP inspection described in the previous section. 2. Place the RUN/STOP sw

Página 7

62-61107-02 e. When performing service and/or maintenance procedures on a refrigeration unit, make certain that the unit is disconnected from the pow

Página 8

62-61107-02 18 CD10 BATT Battery voltage CD11 SBY Standby (electric motor) hours CD12 MOD V Future expansion CD13 REV Software revision CD14 S

Página 9 - MPORTANT

62-61107-02 8. OPTIONAL CONTROL PANEL 8.1. Description Keep the fold out sheet while reading the instructions. User-friendly indicator and operato

Página 10

62-61107-02 20 8.2.1. To change the setpoint Setpoint change can be made from control panel or cab control. 1. Press the UP or DOWN ARROW key (23

Página 11

62-61107-02 21 9. PROBLEMS Everything possible has been done to ensure that your unit is the most reliable, trouble-free equipment available on the

Página 12

62-61107-02 4 8. OPTIONAL CONTROL PANEL ...19 8.1.

Página 13

62-61107-02 22 Other method to reset : move RUN/STOP switch (4.) to STOP. Unit resets and will start when RUN/STOP switch is moved to run position.

Página 14

62-61107-02 23 10.1. Maintenance schedule Unit HOURS 250 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

Página 15

62-61107-02 10.3. Recommended oil Engine oil : the oils recommended for use in your refrigeration unit must comply with the American Petroleum Instit

Página 16

62-61107-02 25 11. A.T.P. EUROPE REGULATION EXTRACT Approval of vehicles intended for the carriage of perishable goods. Before putting a refrigerat

Página 17

62-61107-02 12. 24H ASSISTANCE At Carrier Transicold we're working hard to give you complete service when and where you need it. That implies a

Página 18

62-61107-02 2. IDENTIFICATION Keep the fold out sheet while reading the instructions. 1. Nameplate Each unit is identified by a nameplate attached

Página 19

62-61107-02 AUTOMATIC START UP IN DIESEL WHEN LOSS OF STANDBYFROM EPROM 3.19 – FOR MONO TEMP FROM EPROM 4.05 – FOR MULTI TEMP NOTE : This option mus

Página 20

62-61107-02 Electricity : When this refrigeration unit is running in electrical operation, some devices are powered up especially in the e

Página 21

62-61107-02 c. If refrigerant fluid has been splashed into your eyes, rinse them immediately with clean water. As a precaution, you are recommended

Página 22 - TD+15W-40

62-61107-02 The following symptoms indicate exhaust gas has been inhaled : - Blackout, intense headache, sudden weakness and sleepiness, vomiting

Página 23 - Very important

62-61107-02 10 4. PRODUCT LOADING Proper air circulation in the insulated box, air that can move around and through the load, is a critical element

Página 24

62-61107-02 Load spacers Load on pallets • Leave a free space of about : - 6 to 8 cm between load and frontwall, - 20 cm between the top of t

Comentários a estes Manuais

Sem comentários