Carrier 52S series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aparelhos de ar condicionado "split system" Carrier 52S series. Carrier 52S series Product data Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 48
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
ARCHITECTS AND ENGINEERS’ MANUAL
October 2000 Copyright Carrier Corporation Cat. No. 592-074
CONTENTS
Page
APPLICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
New Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Retrofit/Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . .2
PRODUCT OVERVIEW
. . . . . . . . . . . . . . . . . . . . . . .3
PRODUCT FEATURES AND BENEFITS
. . . . 4-10
Quiet Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Most Efficient Performance . . . . . . . . . . . . . . . . . . . . . .4
Efficient Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
No Rust Weather Last™ Wall Sleeve and
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
One-Piece Washable Indoor Filter . . . . . . . . . . . . . . . . .5
Durable Control Panel Door and
Easy-to-Use Controls . . . . . . . . . . . . . . . . . . . . . . . . .6
Washable Vent Air Filter . . . . . . . . . . . . . . . . . . . . . . . .6
Bi-Directional Discharge Grille . . . . . . . . . . . . . . . . . . .6
Easy Access to Chassis. . . . . . . . . . . . . . . . . . . . . . . . . .7
Hidden Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Enhanced Copper Tubing. . . . . . . . . . . . . . . . . . . . . . . .8
Seamless Basepan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Page
Condensate Drain Valve. . . . . . . . . . . . . . . . . . . . . . . . . 8
Condensate Removal System. . . . . . . . . . . . . . . . . . . . . 8
Carrier Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Heat Pumps Pay Their Own Way. . . . . . . . . . . . . . . . . . 9
Heat Pump Energy Savings . . . . . . . . . . . . . . . . . . . . . 10
ORDERING DATA
. . . . . . . . . . . . . . . . . . . . . . . . 11-20
Product Catalog Number . . . . . . . . . . . . . . . . . . . . . . . 11
Factory-Installed Options. . . . . . . . . . . . . . . . . . . . . . . 12
Field-Installed Accessories . . . . . . . . . . . . . . . . . . . . . 13
DIMENSION DRAWINGS AND
INSTALLATION DATA — NEW
CONSTRUCTION
. . . . . . . . . . . . . . . . . . . . . . . . . 21-26
PRODUCT DATA
. . . . . . . . . . . . . . . . . . . . . . . . . 27-35
WIRING DIAGRAMS
. . . . . . . . . . . . . . . . . . . . . 36-40
GUIDE SPECIFICATIONS
. . . . . . . . . . . . . . . . .41,42
TYPICAL WARRANTY
. . . . . . . . . . . . . . . . . . . .43,44
LITERATURE LIST
. . . . . . . . . . . . . . . . . . . . . . . . . . 45
STANDARD COLORS
. . . . . . . . . . . Inside Back Cover
MODEL 52S
PACKAGED TERMINAL
AIR CONDITIONERS
AND HEAT PUMPS
Vista de página 0
1 2 3 4 5 6 ... 47 48

Resumo do Conteúdo

Página 1 - CONTENTS

ARCHITECTS AND ENGINEERS’ MANUALOctober 2000 Copyright  Carrier Corporation Cat. No. 592-074CONTENTSPageAPPLICATIONS . . . . . . . . . . . . . . . .

Página 2 - APPLICATIONS

10HEAT PUMP ENERGY SAVINGSCARRIER HEAT PUMP INITIAL COST VERSUS SAVINGS OVER HEAT/COOL MODELS* Computer projections based on full cooling load at 95°

Página 3 - PRODUCT OVERVIEW

11For immediate assistance, call 1-800-827-7435.Standard 52S Unit• Chassis with front panel• Electro-mechanical pushbutton control• Cord-connected cha

Página 4 - PRODUCT FEATURES AND BENEFITS

12FACTORY-INSTALLEDOPTIONSWall Thermostat Control (RC)Carrier’s wall thermostat control option includes:• a standard chassis with front panel• factory

Página 5 - Wall Sleeve

13FIELD-INSTALLEDACCESSORIESWeather Last™ Wall SleevePart No.: WALL-SLEEVE-1PKPart No.: WALL-SLEEVE-9PKIt is recommended that a Carrier sleeve be used

Página 6 - (Left Side of Chassis)

14Aluminum ArchitecturalOutdoor Grilles (Louvered)Part No.: GRILLE-ALU-WHITEPart No.: GRILLE-ALU-BRONZPart No.: GRILLE-ALU-BROWNPart No.: GRILLE-ALU-B

Página 7 - Fan Cycle Switch

15Outdoor Grille SelectionCarrier recommends only the use of Carrier-suppliedgrilles for use on the 52S series units. However, thearchitectural design

Página 8 - Water Accumulation

16265-V Cord-Connection KitPart No.: PLUG-265V-15AMPPart No.: PLUG-265V-20AMPPart No.: PLUG-265V-30AMPThis 265-volt cord connection kit is an alternat

Página 9 - Special Features

17Lateral Duct KitPart No.: LAT-DUCT-PLENUM (Adapter Plenum)Part No.: EXTENSION-DUCT (Extension)The accessory lateral duct kit allows one unit to heat

Página 10 - HEAT PUMP ENERGY SAVINGS

18Programmable ThermostatPart No.: TSTATCCPAC01-B (for heat/cool models)Part No.: TSTATCCPHP01-B (for heat pump models)This microcomputer-controlled,

Página 11 - ORDERING DATA

19Accessory Retrofit Kit for GESleevePart No.: GE-RETROFIT-KITThis kit contains the items that allow owners to installa 52S chassis into a plastic or

Página 12 - ORDERING DATA (cont)

2Whether you are designing a new structure or replac-ing the packaged terminal air conditioning units in anexisting building, Carrier will meet your n

Página 13 - Weather Last™ Wall Sleeve

20Accessory Retrofit Kit ForAmana/Trane SleevePart No.: AM-RETROFIT-KITThis kit contains the items that allow owners to installa 52S chassis into an A

Página 14

21TYPICAL WALL INSTALLATIONProper building practices must be used when con-structing a wall opening to support a PTAC wall sleeveand chassis.If practi

Página 15 - Drain Kit

22MINIMUM CLEARANCE FOR OUTDOOR DISCHARGE AIRTYPICAL LATERAL DUCT INSTALLATIONDIMENSION DRAWINGS AND INSTALLATIONDATA — NEW CONSTRUCTION (cont)36"

Página 16

23WALL SLEEVE MOUNTING DIMENSIONS FOR STANDARDAND ACCESSORY GRILLESWall SleeveMinimum Wall Sleeve OpeningWall Sleeve Mounting

Página 17 - Thermostat

2452S WITH SUBBASEDIMENSION DRAWINGS AND INSTALLATIONDATA — NEW CONSTRUCTION (cont)4 3/4”3 1/8”10 3/8”8 1/2”14 7/8”3 3/4”(5) 7/8” DIA. KNOCKOUTS(5) 1

Página 18

25TYPICAL WALL AND DEEP WALL INSTALLATIONNOTES:1. Sleeve may be flush mounted to floor, but front panel mayhave to be notched to accommodate service c

Página 19 - Accessory Retrofit Kit for GE

26DIMENSION DRAWINGS AND INSTALLATIONDATA — NEW CONSTRUCTION (cont)NOTES:1. Unit sleeve and sleeve extension (field fabricated) should beconnected bef

Página 20

27PERFORMANCE AND ELECTRICAL DATAMODEL 52SQ (230/208 V)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310/380-93.†Coefficie

Página 21 - DATA — NEW CONSTRUCTION

28PERFORMANCE AND ELECTRICAL DATAMODEL 52SQ (265 V)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310/380-93.†Coefficient o

Página 22 - 52S Lateral Duct

29PERFORMANCE AND ELECTRICAL DATAMODEL 52SE (230/208 V)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310/380-93.†Electric

Página 23 - AND ACCESSORY GRILLES

3This section summarizes product features covered indetail in later sections: PRODUCT OVERVIEWPolymer Sleeve — Designed for ruggedduty, acoustic absor

Página 24 - 52S WITH SUBBASE

30PERFORMANCE AND ELECTRICAL DATAMODEL 52SE (265 V)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310/380-93.†Electric resi

Página 25 - Typical Wall Installation

31PERFORMANCE AND ELECTRICAL DATAMODEL 52SC (230/208 V)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310/380-93.RECEPTACLE

Página 26

32PERFORMANCE AND ELECTRICAL DATAMODEL 52SC (265 V)LEGENDEER — Energy Efficiency Ratio*Rated in accordance with ARI Standard 310/380-93.†All 265-v uni

Página 27 - PRODUCT DATA

33EXPANDED RATINGS DATACOOLING PERFORMANCE — 52SC, SE, SQ 7000 AND 9000 BTU MODELS(230 AND 265 V)ALL 7000 NOMINAL BTUH MODELSEvaporator entering air t

Página 28 - PRODUCT DATA (cont)

34EXPANDED RATINGS DATA (cont)HEAT PUMP HEATING PERFORMANCE**Heat pump performance is based on 70 F indoor temperature.HEAT PUMP HEATING PERFORMANCE (

Página 29 - RECEPTACLES AND FUSE TYPES

35INDOOR SOUND DATAThe table below indicates the approximate indoorsound level of a 52S unit. Tests were conducted in theCarrier Sound Testing Laborat

Página 30

36WIRING DIAGRAMSLEGENDCAP —CapacitorCOMP —CompressorFCS —Fan Cycle SwitchFM —Fan MotorHTR —HeaterIT —Indoor ThermostatL —Power Supply LineOFT —Outdoo

Página 31

37LEGENDCAP —CapacitorCOMP —CompressorCR —Cooling RelayEQUIPGND—Equipment GroundFM —Fan MotorFR —Fan RelayHR —Heating RelayIFT —Indoor Frost Thermosta

Página 32

38WIRING DIAGRAMS (cont)LEGENDCAP —CapacitorCOMP —CompressorFCS —Fan Cycle SwitchFM —Fan MotorHTR —HeaterIT —Indoor ThermostatL —Power Supply LineLS —

Página 33 - EXPANDED RATINGS DATA

39LEGENDCAP —CapacitorCOMP —CompressorCR —Cooling RelayEQUIPGND—Equipment GroundFM —Fan MotorFR —Fan RelayHR —Heating RelayIFT —Indoor Frost Thermosta

Página 34

4The 52S model is a single-package, through-the-wallunit for heating and cooling hotel rooms, offices,apartments, condominiums, and residential additi

Página 35 - INDOOR SOUND DATA

40WIRING DIAGRAMS (cont)FRONT DESK SWITCH PANEL24-VTRANSFORMER(SEE NOTE)PTAC #1WGWGPTAC #2WGPTAC #NROOM 100 ROOM 101 ROOM NLEGENDNOTES:1. To size tran

Página 36 - WIRING DIAGRAMS

41PACKAGED TERMINAL COOLING UNITWITH HEAT PUMP OR ELECTRIC HEATINGHVAC Guide SpecificationsSize Range: Cooling: 7,100 to 13,700 BtuhHeating: 6,100 to

Página 37

42L. Special Features:Certain standard features are not applicable whenthe features designated are specified. Contactyour local Carrier Sales Office f

Página 38 - WIRING DIAGRAMS (cont)

43TYPICAL WARRANTYFULL ONE-YEAR WARRANTY - During the first year after purchase, CARRIER will,through its authorized independent servicing dealers or

Página 39

44TYPICAL WARRANTY (cont)1. CHECK THE THINGS YOU CAN DO YOURSELF.These include being sure that air conditioner is pluggedfirmly in an appropriate rece

Página 40

45FORM NO. CATALOG NO.Warranty certificate 530-105Installation/Installation, Operating 52S-63SI 535-20014and Maintenance InstructionsLateral Duct Kit,

Página 44 - TYPICAL WARRANTY (cont)

5NO-RUST WEATHER LAST™WALL SLEEVE AND FRONTPANELThe indoor front panel and wall sleeve use nonmetalliccompounds that never rust or corrode, do not sup

Página 45 - LITERATURE LIST

6DURABLE CONTROL PANELDOOR AND EASY-TO-USECONTROLSThe reinforced control door conceals controls and fea-tures an attractive surface that will not chip

Página 46

7EASY ACCESS TO CHASSISAccess to the chassis simply requires removing fourscrews and then sliding the chassis out of the sleevefor service. Once the p

Página 47

8ENHANCED COPPER TUBINGEnhanced copper tubing is more efficient and durableand can be repaired in the field, if required.Because copper is a very stab

Página 48

9HEAT PUMPS PAY THEIR OWNWAYHeat pump models are available at a nominal addi-tional cost. In many locales, the payback is realized injust a few months

Comentários a estes Manuais

Sem comentários